Load Bank IEC60884 – Socket Outlet Test System
Normative Reference: IEC60884-1
Application: Breaking capacity and Normal operation test for sockets and outlets
Compounded by 4 modular systems.
Module 1 – Power Supply for Load Bank:
DNPW884-1
Input voltage: 230 V
Current: 20 A
Frequency: 50 Hz
Isolated transformer output: 250/275 V - 20 A
Module 2 - Automatic Load Bank:
DNPW884-2
Nominal Current
Current Test | Voltage Test | Power Factor | Power Factor |
16 A | 16 A | 250 V | 0.8 |
20A | 275 V | 0.6 |
Operational Selection Steps:
1 – Select the Nominal current: 16 A
2 – Select the Standard test Item: Breaking capacity (0.6), Normal operation (0.8)
3 – Start – Enable automatically the output
4 – Stop – Disable the output
Module 3 - Breaking Capacity Equipment for Normal Operation of Plugs and Socket-Outlets.
DNBC884-1:
Individual one-position device
Options for Actuator:
Pneumatic Actuator DNBC884-1P
Motorized Actuator DNBC884-1M
DNBC884-2:
Dual device performing 2 samples using one power load bank
Options for Actuator:
Pneumatic Actuator DNBC884-2P
Motorized Actuator DNBC884-2M
DNBC884-3:
Four-position device performing 4 samples
Side-by-side displacement, using two power load banks
Options for Actuator:
Pneumatic Actuator DNBC884-3P
Motorized Actuator DNBC884-3M
Module 4: Integrated Power Load Unit
The power integrator unit synchronizes power loss with the endurance test mechanism through the 5" HMI (Human-Machine Interface), as illustrated in the chart of screens you can find in the datasheet (available at download area). It accepts integrations with other modules, such as switch power loads and switch endurance devices made by Dunel.